Pack output
Both load connections go through the external pack connector. Match the exact connector and polarity of the harness. Consult the pack maker for a compatible charger.
The Honcell HCC18650FC combines one cylindrical cell with a protection circuit module and a two-pin JST VH connector.
Red lead from pack positive to pin 1 of the JST VHR-2N.
| Parameter | Limit | Conditions and source |
|---|---|---|
| Rated voltage and capacity3.7 V · 2.6 Ah typical | 3.7 V · 2.6 Ah typical | 2.55 Ah minimum at the manufacturer’s 0.2 C discharge test and 23 ± 2 °C. Honcell HCC18650FC datasheet, § 3 |
| Charge and discharge endpoints4.2 V · 2.75 V | 4.2 V · 2.75 V | Manufacturer charge and discharge figures. Coordinate the equipment’s cutoff with the pack protection circuit, which has separate detection and release thresholds. Honcell HCC18650FC datasheet, §§ 3 and 5.4 |
| Continuous discharge limit2.6 A | 2.6 A | Pack-specific maximum at the stated −20 to +60 °C discharge ambient. Check connector, harness and enclosure ratings separately. Honcell HCC18650FC datasheet, § 3 |
| Pack dimensions67.0 × 19.5 × 22.5 mm max. | 67.0 × 19.5 × 22.5 mm max. | Excludes the connector and the 300 ± 5 mm leads shown in the assembly drawing. Honcell HCC18650FC datasheet, § 4.1 |
This reference covers the bare Molicel INR-18650-P28A and the separately documented Honcell HCC18650FC protected assembly. Check the exact manufacturer code for chemistry, voltage, capacity, load rating, protection and fit.