2N7000 N-channel MOSFET connection guide
2N7000 N-channel MOSFET TO-92 formed leads wiring guide with power, signal assignments, and bench checks.
TO-92 formed leads
3 contacts Current packageWire the common return and gate pull-down
RequiredKeep both supplies off. Connect source and both supply returns together. Fit a 100 kΩ resistor from G to S to define the off state when the gate jumper is open. Use an ESD-safe work area.
Bench checks
- Verify the flat-face lead order and that R2 connects to G and S. Set the load supply to 5 V with a 10 mA limit and the gate supply to 10 V with a 1 mA limit.
onsemi NDS7002A/D Rev. 11, pp. 1–3; onsemi 2N7000TA/D Rev. 1, pp. 1–2. The pull-down and limits are bench choices.
Connection scenarios
Identify the intrinsic diode
Disconnect both supplies and remove the MOSFET from any parallel circuit paths. Short G to S to discharge the gate. Select diode-test mode and probe from S to D.
Bench checks
- Expect a forward reading with the red probe on S and the black probe on D. Reverse the probes while keeping G shorted to S and expect an open reading.
- Consult the meter manual for test polarity and current. The displayed forward voltage depends on the test current and device temperature.
onsemi NDS7002A/D Rev. 11, p. 1, device symbol. Bench meter results depend on its test conditions.
TO-92 formed leads wiring map
3 · D
Connect to the low side of the load in a low-side switch. The intrinsic body diode has its cathode here.
Models and documents
onsemi TO-92 cases 135AN and 135AR. The 2N7000BU and 2N7000TA order codes use a separate electrical table. The SOT-23 2N7002 and NDS7002A have a different lead map and their own ratings.
- 2N7000-D26Z
- Tape-and-reel code in NDS7002A/D p. 7.
- 2N7000-D74Z
- Ammo code in NDS7002A/D p. 7. Confirm the supplied lead form against the package drawing.
- 2N7000-D75Z
- Tape-and-reel code in NDS7002A/D p. 7. Confirm the supplied lead form against the package drawing.
- 2N7000TA
- Fan-fold code in 2N7000TA/D.
- onsemi 2N7000 datasheet· NDS7002A/D · Rev. 11 · March 2025 · 2N7000 electrical column, ordering and both TO-92 outlines.
- onsemi 2N7000BU / 2N7000TA datasheet· 2N7000TA/D · Rev. 1 · July 2023 · Variant-specific ratings and ordering.
- Source register· Manufacturer URLs, applicability and file checksums.