74HC4053 connection guide
Wire a 5 V bench circuit and test both throws of each Texas Instruments CD74HC4053 switch.
Connect the power and bypass capacitor
With power off, connect a regulated +5 V supply to VCC (16). Join VEE (7) and GND (8) at the supply return. Fit one 100 nF ceramic capacitor between VCC and GND close to the chip.
Complete the signal and control wiring below before applying power. With meter common at pin 8, verify +5 V at pin 16 and 0 V at pin 7.
Choose a switch group and signal path
Wire group B · Throw 1 · HIGH
Disable both signal sources and turn off the IC supply before moving jumpers. Connect 1 V DC to B0 (2) and 4 V DC to B1 (1). Join both source returns and the meter common to GND (8). Place the meter’s positive probe on COM B (15). Use a high-impedance meter or a scope input of 1 MΩ or higher.
Set these control pins with jumpers to the rails. Leave the other groups’ analog terminals open. Turn on the IC supply before enabling the two signal sources.
Lines show bidirectional switch paths.
Verify the result at COM B
With power on, the meter should read approximately 4 V relative to GND. If it reads the other source, check S1 at pin 10. If neither level appears, check pin numbering, the source returns and EN at pin 6.
Keep every driven analog pin within 0 to +5 V in this circuit, including the unselected throw. Apply signals with the IC powered. See the electrical limits.
Package and documents
NS · 10.2 × 5.3 mm nominal body · 1.27 mm lead pitch. Use TI drawing 4220735/A for footprint dimensions and tolerances.
Order codes in TI’s 7 October 2026 addendum:
- Not recommended for new designs: CD74HC4053NSR, CD74HC4053NSR.A.
- TI CD74HC4053 datasheet (PDF)· SCHS122O, revision O (January 2026), with package option addendum
- TI CD74HC4053 product and ordering information
Pin assignments: Figure and Table 4-3 (p. 5). Switching: Figure 7-3 and Table 7-3 (pp. 24–25). Supply bypass: § 8.3 (p. 27). Order codes and package drawings follow the datasheet.