Spark Logic

ACS712 Hall-effect current sensor pinout

The ACS712 reports the current in its integrated conductor as an analog voltage centered on half the sensor supply.

LC SOIC-8

8 contacts Current package

Allegro MicroSystems · Allegro LC, 8-lead narrow small-outline package.

±5 A optimized range, 185 mV/A typical at 5 V and 25 °C.

LC SOIC-8 pinout

Top view. Locate the package index before counting counterclockwise from pin 1.
Selected pin details

5 · GND

Return · Ground

Signal-side reference for the supply, output and filter capacitor.

Allegro ACS712-DS Rev. 22, pinout diagram

Electrical limits · Link to this pin

All 8 pins

PinSignalDirectionFunction
1IP+ Primary conductorPrimary conductor First lead of the internally common positive current terminal. Join to pin 2.
2IP+ Primary conductorPrimary conductor Second lead of the positive current terminal. Join to pin 1.
3IP− Primary conductorPrimary conductor First lead of the internally common negative current terminal. Join to pin 4.
4IP− Primary conductorPrimary conductor Second lead of the negative current terminal. Join to pin 3.
5GND ReturnReturn Signal-side reference for the supply, output and filter capacitor.
6FILTER Filter nodeFilter node A capacitor here to GND limits the output bandwidth.
7VIOUT OutputOutput Ratiometric voltage output. Current from IP+ toward IP− raises this voltage.
8VCC SupplySupply Nominal 5 V supply. Bypass near this lead to GND.

Signal assignments

Primary current path

Use both leads of each primary terminal. The sample current flows through the integrated copper conductor in series with the load.

Analog output

Calculate current from the voltage difference relative to the measured zero-current output. The slope depends on the part suffix and supply voltage.

Electrical limits

ParameterLimitConditions and source
Optimized range±5 A±5 A See the thermal data for PCB and ambient conditions. Allegro ACS712-DS Rev. 22
Sensitivity185 mV/A typical185 mV/A typical At 5 V and 25 °C. Allegro ACS712-DS Rev. 22
Sensor supply4.5–5.5 V4.5–5.5 V 5 V nominal. Allegro ACS712-DS Rev. 22, common operating characteristics
Zero-current outputVCC ÷ 2 nominalVCC ÷ 2 nominal Offset varies with temperature. Record the actual zero before measuring current. Allegro ACS712-DS Rev. 22
Conductor resistance1.2 mΩ typical1.2 mΩ typical Primary conductor. PCB copper and heat sinking determine practical current capability. Allegro ACS712-DS Rev. 22

Models and documents

The LC-package sensing ranges share one terminal map. Match the exact suffix before converting voltage to amperes.

ACS712ELCTR-05B-T
±5 A optimized range, 185 mV/A typical at 5 V and 25 °C.
ACS712ELCTR-20A-T
±20 A optimized range, 100 mV/A typical at 5 V and 25 °C.
ACS712ELCTR-30A-T
±30 A optimized range, 66 mV/A typical at 5 V and 25 °C.
ACS712ELCTR-20A-S
±20 A optimized range, 100 mV/A typical at 5 V and 25 °C.
ACS712ELCTR-30A-S
±30 A optimized range, 66 mV/A typical at 5 V and 25 °C.
  • Allegro ACS712-DS Rev. 22· Selection guide, package drawing, terminal functions and sensitivity tables.
  • Source register· Document revisions, applicable order codes, consulted sections and available file checksums.