AZ1117C low dropout regulator connection guide
AZ1117C low dropout regulator (SOT-89 R) connection guide. Wire the regulator for about 9 V.
SOT-223 H 4 contacts
SOT-223 H2 4 contacts
SOT-89 R
4 contacts Current packageSOT-89 R2 4 contacts
TO-252 D 4 contacts
Wire the regulator for about 9 V
RequiredCheck the package code and the tab net before soldering. Bypass the input and output close to the part. Use at least 10 µF effective output capacitance and less than 20 Ω ESR.
- Input
- CIN.1
- Current-limited 11 V supply
- Output
- →
- COUT.1
- Meter positive
- R1.1
- Ground
- CIN.2
- COUT.2
- Supply return
- Meter common
- R2.2
- Feedback
- →
- R1.2
- R2.1
Bench checks
- Verify pin and tab continuity with power off. Do not let a heatsink short the tab to another net.
- Measure about 1.25 V across R1 and about 9 V from OUT to ground. The divider draws roughly 10 mA, above the 5 mA maximum minimum-load specification.
Diodes DS36676 Rev. 5-2, p. 3, Typical Applications Circuit and note 4.
SOT-89 R wiring map
SOT-89 R
1 · ADJ
Feedback pin. The regulator maintains about 1.25 V from OUT to ADJ.
Models and documents
The second line 816TI5 fits the SOT-223 YWWAXX traceability format (year digit 8, work week 16, assembly code T, batch suffix I5). The format does not identify the decade. The D variants share their electrical assignment, but the short center lead and package drawing options require checking the land pattern.
- AZ1117CR-ADJTRG1
- Adjustable output. Marking: G27N.
- AZ1117CR-1.2TRG1
- 1.2 V fixed output. Marking: G28J.
- AZ1117CR-1.5TRG1
- 1.5 V fixed output. Marking: G28K.
- AZ1117CR-1.8TRG1
- 1.8 V fixed output. Marking: G28L.
- AZ1117CR-2.5TRG1
- 2.5 V fixed output. Marking: G28M.
- AZ1117CR-3.3TRG1
- 3.3 V fixed output. Marking: G28N.
- AZ1117CR-5.0TRG1
- 5.0 V fixed output. Marking: G27M.
- Datasheet for AZ1117C· DS36676 Rev. 5-2; see pp. 2–4 for wiring and pp. 11–12 for order and marking codes.