BH1750 ambient light sensor connection guide
BH1750 ambient light sensor WSOF-6I wiring guide with power, signal assignments, and bench checks.
WSOF-6I
7 contacts Current packageConnect an I²C host
RequiredUse the manufacturer’s host-controlled DVI circuit. Choose a GPIO that can drive the bypass capacitance and maintain DVI near 3.3 V after reset. Tie ADDR to ground and leave the underside pad electrically isolated.
- +3.3 V
- VCC (1)
- Host 3.3 V
- C1.1
- R1.1
- R2.1
- Ground
- I²C data
- SDA (4)
- Host SDA
- R1.2
- I²C clock
- SCL (6)
- Host SCL
- R2.2
- Reset and interface reference
- DVI (5)
- Host push-pull reset control
- C2.1
Bench checks
- Observe VCC and DVI during startup. Confirm DVI remains low for at least 1 µs after VCC is in range, then rises to the bus reference. Keep the bus idle during reset.
- Find address 0x23. Send power-on (0x01) and one-time high-resolution mode (0x20), with a STOP after each command. Wait 180 ms and read two bytes.
- At the default measurement-time setting, divide the unsigned result by 1.2 for lux. Cover and uncover the sensor and compare the readings.
ROHM BH1750FVI Technical Note, Rev. D (November 2011), pp. 2, 6–10, 13 and 16–17. Manufacturer PDF hosted by Mouser.
WSOF-6I wiring map
EP is the exposed center pad on the underside.
4 · SDA
Open-drain I²C data. The bus needs a pull-up to its logic rail.
Models and documents
The map applies to the bare BH1750FVI. Breakout modules may supply DVI from separate circuitry.
- BH1750FVI-TR
- WSOF-6I, tape and reel.
- BH1750 manufacturer documentation· ROHM BH1750FVI Technical Note, Rev. D (November 2011), pp. 2, 6–10, 13 and 16–17. Manufacturer PDF hosted by Mouser.