BME280 humidity and pressure sensor connection guide
BME280 humidity and pressure sensor LGA-8 · 2.5 × 2.5 mm wiring guide with power, signal assignments, and bench checks.
LGA-8 · 2.5 × 2.5 mm
8 contacts Current packageConnect an I²C host
RequiredPower the bare sensor and host from 3.3 V. Tie CSB to VDDIO and SDO to ground for address 0x76. Use 0x77 if SDO is tied to VDDIO.
Bench checks
- At 100 kHz on a short bus, find an acknowledgement at the address selected by SDO.
- Read chip ID register 0xD0. A BME280 production part returns 0x60.
- Read the factory calibration coefficients and use the manufacturer’s compensation algorithm for each enabled measurement.
Bosch Sensortec BST-BME280-DS001-24, §§ 1, 5–7.
Connection scenarios
Connect a 4-wire SPI host
Use a 3.3 V SPI host with separate data lines. Keep chip select high at idle and pull it low for each transaction.
- +3.3 V
- Ground
- Chip select
- CSB (2)
- Host CS
- Serial clock
- SCK (4)
- Host SCK
- Host to sensor
- SDI (3)
- Host MOSI
- Sensor to host
- SDO (5)
- Host MISO
Bench checks
- Start at 1 MHz in mode 0. To read the ID, send 0xD0 and clock in the next byte with CSB held low.
- Read chip ID register 0xD0. A BME280 production part returns 0x60.
- Read the factory calibration coefficients and use the manufacturer’s compensation algorithm for each enabled measurement.
Bosch Sensortec BST-BME280-DS001-24, §§ 1, 5–7.
LGA-8 · 2.5 × 2.5 mm wiring map
1 · GND
Connect to the common ground plane or bench return.
Models and documents
This map is for the bare LGA sensor. Breakout headers and logic-voltage limits depend on the board.
- 0 273 141 185
- Bosch sales part number.
- BME280 manufacturer documentation· Bosch Sensortec BST-BME280-DS001-24, §§ 1, 5–7.