BMP085 digital pressure sensor connection guide
BMP085 digital pressure sensor LCC-8 · 5.0 × 5.0 mm wiring guide with power, signal assignments, and bench checks.
LCC-8 · 5.0 × 5.0 mm
8 contacts Current packageConnect an I²C host
RequiredUse one 3.3 V rail for VDDA, VDDD, and the host. Tie XCLR high. The host can time conversion in software and leave EOC open.
Bench checks
- Look for an acknowledgement at 7-bit address 0x77 and read the 22 calibration bytes from 0xAA through 0xBF.
- Start a temperature conversion by writing 0x2E to 0xF4. Wait at least 4.5 ms, then read the result starting at 0xF6. Follow the datasheet procedure for the separate pressure conversion.
Bosch Sensortec BMP085 Rev. 1.0 (July 2008), §§ 1, 3–5. Manufacturer document mirrored by jensd.dk.
LCC-8 · 5.0 × 5.0 mm wiring map
LCC-8 · 5.0 × 5.0 mm
4 · VDDD
Digital supply. Set the I²C pull-up rail to this logic voltage.
Models and documents
This map covers the ceramic LCC-8 device.
- BMP085
- Ceramic package.
- BMP085 manufacturer documentation· Bosch Sensortec BMP085 Rev. 1.0 (July 2008), §§ 1, 3–5. Manufacturer document mirrored by jensd.dk.