BQ24010 single-cell linear charger connection guide
BQ24010 single-cell linear charger DRC VSON-10 wiring guide with power, signal assignments, and bench checks.
DRC VSON-10
11 contacts Current package3 × 3 mm DRC0010J package, −40 to +85 °C catalog operating ambient.
Set up the charger with a battery simulator
RequiredUse a 3.6 V battery simulator that can sink the programmed charge current. The fixed TS divider represents a normal-temperature pack for this bench test. Use the thermistor network in Figure 3 with a real battery.
- 5 V input
- Ground
- Simulated battery positive
- Charge-current setting
- ISET (6)
- RSET.1
- Simulated normal temperature
- TS (8)
- RT1.2
- RT2.1
Bench checks
- Before powering IN, verify continuity from VSS and the exposed pad to ground and confirm the simulator polarity.
- With IN at 5 V, check that TS is near 2.5 V and fast-charge current is about 0.10 A at a 3.6 V simulated battery.
Texas Instruments SLUS530K, Figure 3 and Equation 4. Current is 335 × 2.50 V ÷ 8.25 kΩ nominal.
Connection scenarios
Read the power and charge outputs
On the same simulator fixture, pull PG, STAT1 and STAT2 up individually to the 5 V bench rail through 10 kΩ resistors.
- 5 V input
- Ground
- Simulated battery positive
- Charge-current setting
- ISET (6)
- RSET.1
- Simulated normal temperature
- TS (8)
- RT1.2
- RT2.1
- Input power status
- PG (7)
- RPG.2
- 5 V logic probe
- Charge status 1
- STAT1 (3)
- RS1.2
- 5 V logic probe
- Charge status 2
- STAT2 (4)
- RS2.2
- 5 V logic probe
Bench checks
- Check PG low when valid input is present and compare STAT1 and STAT2 against the charge-status table.
Texas Instruments SLUS530K, Status Outputs and Figure 3. The pull-up values are fixture choices.
DRC VSON-10 wiring map
EP is the exposed center pad on the underside.
3 · STAT1
Open-collector charge status output 1. Use a pull-up or LED resistor to observe it.
Models and documents
The DRC pinout applies to BQ24010. Other bqTINY parts substitute CE or TTE for some of the BQ24010 functions.
- BQ24010DRCR
- 3 × 3 mm DRC0010J package, −40 to +85 °C catalog operating ambient.
- BQ24010DRCR.A
- 3 × 3 mm DRC0010J package, −40 to +85 °C catalog operating ambient.
- Texas Instruments SLUS530K· Rev. K, January 2014. Device information, current setting, temperature supervision and typical circuit.
- Source register· Document revisions, applicable order codes, consulted sections and available file checksums.