DS1621 digital thermometer connection guide
DS1621 digital thermometer PDIP-8 · 300 mil wiring guide with power, signal assignments, and bench checks.
Connect an I²C host
RequiredTie all address inputs low for address 0x48. Use this circuit to read temperature and leave TOUT open unless you need the thermostat signal.
- +3.3 V
- VDD (8)
- Host 3.3 V
- C1.1
- R1.1
- R2.1
- Ground
- I²C data
- SDA (1)
- Host SDA
- R1.2
- I²C clock
- SCL (2)
- Host SCL
- R2.2
Bench checks
- Confirm an acknowledgement at 0x48. Send 0xEE, then poll bit 7 (DONE) with Access Config (0xAC).
- Read both bytes using command 0xAA. Interpret the high nine bits as a signed value in units of 0.5 °C.
Analog Devices / Maxim DS1621 Rev. 4, pp. 1–5 and 8–12.
PDIP-8 · 300 mil wiring map
1 · SDA
Open-drain I²C data. The bus needs a pull-up to its logic rail.
Models and documents
Package maps follow the manufacturer’s package drawings. Use the package code on the actual part to distinguish narrow and wide SO bodies.
- DS1621+
- Through-hole package.
- DS1621 manufacturer documentation· Analog Devices / Maxim DS1621 Rev. 4, pp. 1–5 and 8–12.