GStek GS72V3 synchronous buck controller connection guide
GStek GS72V3 synchronous buck controller (PSOP-8 (SP)) connection guide. Check supply and startup. Trace the bootstrap and MOSFET stage.
PSOP-8 (SP)
9 contacts Current packageCheck supply and startup
RequiredOn an unpowered board, identify the controller supply at pin 5 and the separate VIN connection at the high-side MOSFET drain. Some boards use the same rail for both. Keep the existing VCC bypass capacitor and COMP/EN compensation network in circuit.
- Controller supply
- VCC bypass capacitor positive
- Controller supply rail
- Power-stage input
- Power-stage VIN rail
- High-side MOSFET drain
- VIN bulk capacitor positive
- Ground
- VCC bypass capacitor return
- Power-stage input capacitor return
- Bench supply return
- Shutdown and compensation
- Existing compensation network
- Open-drain shutdown control when fitted
Bench checks
- With power off, verify pin 3 and EP9 connect to board ground and check both supply rails for shorts. Use a current-limited supply at the board’s rated input voltage.
- Check for 4.5–13.2 V from pin 5 to GND and verify the MOSFET drain supply separately. VCC above the power-on threshold does not prove that VIN has reached the power stage.
- Check whether an external transistor holds COMP/EN below 0.3 V. Release the pull-down to allow startup. Applying a logic-high drive here interferes with the error amplifier.
GStek GS72V3, rev. 0.4, pp. 3, 5–6, 9
Connection scenarios
PSOP-8 (SP) wiring map
Dashed outline shows the underside pad schematically. See the package drawing for the footprint.
4 · LGATE
Drives the external low-side N-channel MOSFET. Measure relative to the low-side source at ground.
Models and documents
The pin map and measurements use the full rev. 0.4 datasheet for GS72V3SP-R. The rev. 1.0 product brief shows a different overcurrent setting network. Check the board and document revision before interpreting current limit or replacing its parts.
- GS72V3SP-R
- PSOP-8 (SP) in tape and reel.
- GS72V3 datasheet, rev. 0.4 (March 2012)· External copy of the full GStek datasheet. See pp. 2–4 for the package and ordering code, pp. 5–6 for limits, and pp. 9–13 for operation and application information.
- GS72V3 product brief, rev. 1.0 (April 2015)· External copy of the later GStek brief. Its drawing and overcurrent description differ from rev. 0.4.