ICL7660 inverting charge pump pinout

The ICL7660 transfers charge through a flying capacitor to create a small negative supply from a positive rail.

PDIP-8 8 contacts

SOIC-8

8 contacts Current package

Renesas / Intersil · Surface-mount narrow M8.15 outline.

1.5 to 10 V operating supply, 0 to 70 °C.

SOIC-8 pinout

Top view. Locate the package index before counting counterclockwise from pin 1.
Selected pin details

1 · NC

No connection · NC / reserved

Leave open. The ICL7660S has a different function at this position.

Renesas / Intersil FN3072 Rev. 7.00, p. 1

Electrical limits · Link to this pin

All 8 pins

PinSignalDirectionFunction
1NC No connectionNo connection Leave open. The ICL7660S has a different function at this position.
2CAP+ BidirectionalBidirectional Positive plate of the charge-transfer capacitor.
3GND ReturnReturn Input and output reference. Positive plate of the output reservoir capacitor.
4CAP− BidirectionalBidirectional Negative plate of the charge-transfer capacitor.
5VOUT OutputOutput Negative output. Its unloaded magnitude approaches the input voltage.
6LV InputInput Ground for low-voltage operation below 3.5 V. Leave open above 3.5 V.
7OSC Oscillator nodeOscillator node Leave open to use the internal oscillator unmodified.
8V+ SupplySupply Positive input supply.

Signal assignments

Electrical limits

ParameterLimitConditions and source
Input supply1.5–10 V1.5–10 V Ground LV below 3.5 V. Leave LV open above 3.5 V. Renesas / Intersil FN3072 Rev. 7.00, electrical specifications
Oscillator frequency10 kHz typical10 kHz typical Unloaded oscillator at V+ = 5 V with OSC open. Renesas / Intersil FN3072 Rev. 7.00
Ideal unloaded output−V+−V+ Losses and output impedance reduce the magnitude under load. Renesas / Intersil FN3072 Rev. 7.00, Figure 13

Models and documents

The original ICL7660 and ICL7660A share the same contact functions. The ICL7660S has a frequency boost pin where this map shows NC.

ICL7660CBA
1.5 to 10 V operating supply, 0 to 70 °C.
ICL7660CBA-T
1.5 to 10 V operating supply, 0 to 70 °C.
ICL7660CBAZ
1.5 to 10 V operating supply, 0 to 70 °C.
ICL7660CBAZ-T
1.5 to 10 V operating supply, 0 to 70 °C.
ICL7660CBAZA
1.5 to 10 V operating supply, 0 to 70 °C.
ICL7660CBAZA-T
1.5 to 10 V operating supply, 0 to 70 °C.
ICL7660ACBA
1.5 to 12 V operating supply, 0 to 70 °C.
ICL7660ACBA-T
1.5 to 12 V operating supply, 0 to 70 °C.
ICL7660ACBAZA
1.5 to 12 V operating supply, 0 to 70 °C.
ICL7660ACBAZA-T
1.5 to 12 V operating supply, 0 to 70 °C.
ICL7660AIBA
1.5 to 12 V operating supply, −40 to +85 °C.
ICL7660AIBA-T
1.5 to 12 V operating supply, −40 to +85 °C.
ICL7660AIBAZA
1.5 to 12 V operating supply, −40 to +85 °C.
ICL7660AIBAZA-T