Spark Logic

IRLB3034 N-channel MOSFET connection guide

IRLB3034 N-channel MOSFET TO-220AB wiring guide with power, signal assignments, and bench checks.

TO-220AB

4 contacts Current package

Infineon / International Rectifier · Three lead positions and a connected metal tab.

Check that the switch is off

Required

Use a current-limited 5 V supply and a 1 kΩ resistive load. Pull the gate down to its source through 10 kΩ.

  • 5 V
    • Current-limited 5 V supply
    • RL.1
  • Switched node
  • Return
    • S (3)
    • Supply return
    • Gate supply return
    • RPD.2
    • Meter common
  • Gate
RL 1 kΩ between 5 V and Switched node5 VRL 1 kΩSwitched node
RPD 10 kΩ between Gate and ReturnGateRPD 10 kΩReturn

Bench checks

  • VGS should be approximately 0 V, and the switched node should sit near 5 V.

International Rectifier IRLB3034PbF, terminal diagram and electrical characteristics. The resistors are fixture choices.

Connection scenarios

Switch on a small resistive load

Use a 0/5 V gate drive through 100 Ω. Keep the 10 kΩ pull-down in place to define the state when the gate driver is disconnected.

  • 5 V
    • Current-limited 5 V supply
    • RL.1
  • Switched node
  • Return
    • S (3)
    • Supply return
    • Gate supply return
    • RPD.2
    • Meter common
  • Gate
  • Drive
    • Gate-driver output
    • RG.1
RL 1 kΩ between 5 V and Switched node5 VRL 1 kΩSwitched node
RPD 10 kΩ between Gate and ReturnGateRPD 10 kΩReturn
RG 100 Ω between Drive and GateDriveRG 100 ΩGate

Bench checks

  • With the gate near 5 V relative to source, the switched node should fall close to ground and the load current should be about 5 mA.
  • The threshold voltage describes the onset of conduction. Use the specified on-resistance at the actual gate drive to estimate load losses.

International Rectifier IRLB3034PbF, electrical characteristics. Supply, gate drive and resistors are fixture choices.

TO-220AB wiring map

Highlighted contacts are used in the required step or selected circuit. Select a contact to inspect it.

TO-220AB
View from the marked face, with the tab above the body and leads 1–3 below from left to right. Scroll the map to reach all contacts.
Selected pin details

TAB · D

Bidirectional · Bidirectional

Metal tab connected to D internally. Include its net when laying out the footprint.

International Rectifier IRLB3034PbF, TO-220AB outline and lead assignments

Electrical limits · Pin in the reference

Models and documents

TO-220AB. The mounting tab is electrically connected to the drain.

IRLB3034PBF
Infineon through-hole order code.