Spark Logic

DS212 oscilloscope pinout

The DS212 is a rechargeable pocket oscilloscope with two analog inputs and a built-in signal generator.

DS212 external ports

7 contacts Current package

Miniware / e-Design · Two MCX inputs, a coaxial generator output and Micro-USB.

DS212 external ports pinout

CH A · upper left
Viewed with the screen facing you.
CH B · middle left
Viewed with the screen facing you.
OUT · lower left
Generator output. The center carries the waveform.
USB · right edge
Use a standard Micro-USB cable.
Selected pin details

USB · USB

Charging and data · Bidirectional

Micro-USB port for battery charging and access to the internal disk.

e-Design DS212 User Manual Rev. 1.1, Device Layout, Quick Start Guide and Calibration.

Electrical limits · Link to this pin

All 7 pins

PinSignalDirectionFunction
CH A centerCHA Analog inputAnalog input Channel A signal on the MCX center contact.
CH A shellCHA_GND Analog returnAnalog return Channel A probe return on the MCX shell.
CH B centerCHB Analog inputAnalog input Channel B signal on the MCX center contact.
CH B shellCHB_GND Analog returnAnalog return Channel B probe return on the MCX shell.
OUT centerGEN_OUT Signal generator outputSignal generator output Connect the generator to an input for a functional loopback check.
OUT shellGEN_GND Generator returnGenerator return Outer coaxial contact for the generator output return.
USBUSB Charging and dataCharging and data Micro-USB port for battery charging and access to the internal disk.

Signal assignments

USB charging and data

Disconnect USB for the battery-powered measurement example.

Electrical limits

ParameterLimitConditions and source
Analog input impedance1 MΩ1 MΩ Per analog channel. e-Design DS212 User Manual Rev. 1.1, Device Layout, Quick Start Guide and Calibration.
Analog bandwidth1 MHz1 MHz Manufacturer’s specified analog bandwidth. e-Design DS212 User Manual Rev. 1.1, Device Layout, Quick Start Guide and Calibration.
Maximum sample rate10 MSa/s10 MSa/s Manufacturer’s maximum. e-Design DS212 User Manual Rev. 1.1, Device Layout, Quick Start Guide and Calibration.
×1 input limit±40 V specified±40 V specified The manual instructs users to stay below 40 V for DC input. The loopback example is below 5 V. e-Design DS212 User Manual Rev. 1.1, Device Layout, Quick Start Guide and Calibration.
CouplingAC or DCAC or DC Choose DC to display a waveform’s offset. e-Design DS212 User Manual Rev. 1.1, Device Layout, Quick Start Guide and Calibration.

Models and documents

The map covers the external analog sockets and the USB port on the DS212 in the manufacturer’s Rev. 1.1 manual. USB is shown at connector level.

DS212
Connector layout from e-Design DS212 User Manual Rev. 1.1.