USB data pair
Keep the D+ and D− polarity consistent at the connector and the bridge. Use the package-specific application circuit for matching and bypass components.
FT232RL is the SSOP-28 version of the FT232R bridge. It integrates the USB transceiver, internal clock and EEPROM and has a separate VCCIO supply.
Active-low reset. The internal power-on reset handles a normal bus-powered start.
| Pin | Signal | Direction | Function |
|---|---|---|---|
| 1 | TXD Output | Output | Asynchronous transmit. Connect to the receiver of the external logic-level UART. |
| 2 | DTR# Output | Output | Data Terminal Ready, active low. |
| 3 | RTS# Output | Output | Request to Send, active low. |
| 4 | VCCIO Supply input | Supply input | Sets the UART and configurable pin logic levels. |
| 5 | RXD Input | Input | Asynchronous receive. Connect to the transmitter of the external logic-level UART. |
| 6 | RI# Input | Input | Ring Indicator, active low. |
| 7 | GND Return | Return | Connect to the circuit ground plane. |
| 8 | NC Unconnected | Unconnected | Leave open for this circuit. |
| 9 | DSR# Input | Input | Data Set Ready, active low. |
| 10 | DCD# Input | Input | Data Carrier Detect, active low. |
| 11 | CTS# Input | Input | Clear to Send, active low. |
| 12 | CBUS4 Configurable output | Configurable output | EEPROM-configurable output. The factory function is SLEEP#. |
| 13 | CBUS2 Configurable | Configurable | The internal EEPROM selects the function. See the CBUS options table for available configurations. |
| 14 | CBUS3 Configurable | Configurable | The internal EEPROM selects the function. See the CBUS options table for available configurations. |
| 15 | USBDP Bidirectional | Bidirectional | USB D+ line. Route with the other data line as a differential pair and use the manufacturer’s reference circuit. |
| 16 | USBDM Bidirectional | Bidirectional | USB D− line. Route with the other data line as a differential pair and use the manufacturer’s reference circuit. |
| 17 | 3V3OUT Regulator output | Regulator output | Nominal 3.3 V regulator output. Bypass to ground with 100 nF. |
| 18 | GND Return | Return | Connect to the circuit ground plane. |
| 19 | RESET# Input | Input | Active-low reset. The internal power-on reset handles a normal bus-powered start. |
| 20 | VCC Supply input | Supply input | Main supply input. Connect to the specified operating rail and decouple locally. |
| 21 | GND Return | Return | Connect to the circuit ground plane. |
| 22 | CBUS1 Configurable | Configurable | The internal EEPROM selects the function. See the CBUS options table for available configurations. |
| 23 | CBUS0 Configurable | Configurable | The internal EEPROM selects the function. See the CBUS options table for available configurations. |
| 24 | NC Unconnected | Unconnected | Leave open for this circuit. |
| 25 | AGND Return | Return | Connect to the ground plane with the other return leads. |
| 26 | TEST Input | Input | Tie to ground for normal operation. |
| 27 | OSCI Input | Input | External 12 MHz oscillator input. Leave open when using the internal oscillator. |
| 28 | OSCO Output | Output | External 12 MHz oscillator output. Leave open when using the internal oscillator. |
Keep the D+ and D− polarity consistent at the connector and the bridge. Use the package-specific application circuit for matching and bypass components.
Use the receive and transmit pair with a common ground. The signals use logic-level voltages. A separate transceiver is needed for bipolar RS-232.
| Parameter | Limit | Conditions and source |
|---|---|---|
| VCC with internal oscillator4.0–5.25 V | 4.0–5.25 V | Use the 5 V VBUS circuit. Refer to §7.6 for operation with an external oscillator and a lower supply. FTDI FT_000053, version 2.12, §3.2 note 1 |
| VCCIO1.8–5.25 V | 1.8–5.25 V | Set this rail to suit the connected UART logic. The guide uses the internal 3.3 V output. FTDI FT_000053, version 2.12, Table 3.2 |
The interactive map covers FT232RL in SSOP-28. FT232RQ in QFN-32 has different pin numbers. Use the FT232R datasheet §3.3 for that package.